Tramore Tap Water Quality

EPA monitoring records for Water Supply Zones mapped to Tramore contain 1,862 monitoring results across 69 parameters in 2025.

The separate EPA exceedance dataset contains 13 listed exceedance records across 6 parameters.

The most frequently listed were Aluminium (5), pH (3) and Colony Count @ 22°C (2).

These are historical monitoring records and do not confirm the current status of water at a specific address. Current notices are maintained by Uisce Éireann.

Latest monitoring year
2025
Page updated
September 2026
Water Supply Zone
East Waterford Water Supply Scheme
Geographic overlap
94.03%
1,862Monitoring results
69Parameters tested
13EPA-listed exceedances
107Samples

The Tramore Built Up Area overlaps East Waterford Water Supply Scheme across approximately 94.03% of its land area.

Monitoring results apply to the Water Supply Zone as a whole and may include sampling locations outside Tramore.

Selected monitoring data

Key drinking water parameters

Parameters are shown when measurements are available. Text-only and censored values remain unchanged in the detailed history.

Lead

2025 median1
2025 maximum1
Measurements in 20257

0 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

4 numeric measurements available; 29 text-only records retained in JSON.

Nitrate

2025 median9.89
2025 maximum15.1
Measurements in 20257

0 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

34 numeric measurements available; 0 text-only records retained in JSON.

E. coli

2025 median0
2025 maximum0
Measurements in 2025107

0 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

456 numeric measurements available; 0 text-only records retained in JSON.

Coliform Bacteria

2025 median0 100ml
2025 maximum4 100ml
Measurements in 2025107

1 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

456 numeric measurements available; 0 text-only records retained in JSON.

Fluoride

2025 median0.8
2025 maximum0.8
Measurements in 20257

0 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

33 numeric measurements available; 1 text-only records retained in JSON.

Iron

2025 median20 ug/l
2025 maximum233 ug/l
Measurements in 2025107

1 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

114 numeric measurements available; 335 text-only records retained in JSON.

Arsenic

2025 median—
2025 maximum—
Measurements in 20257

0 EPA-listed exceedances in 2025.

View parameter history

Individual numeric measurements from 2021–2025. Text-only and censored results are retained in the history JSON and are not plotted as numbers.

Open this chart to load the measurements.

Numeric resultEPA-listed exceedance

0 numeric measurements available; 34 text-only records retained in JSON.

20251,862 results · 13 listed exceedances
Total results — independent scale
0 931 1,862 1,193 2021 1,480 2022 1,647 2023 1,700 2024 1,862 2025
Listed exceedances per 1,000 results — independent scale
0.000 3.491 6.982 1.676 2021 6.081 2022 2.429 2023 0.588 2024 6.982 2025

This is our descriptive frequency: listed exceedance records divided by result records, multiplied by 1,000. It is not an official EPA compliance rate. Differences in sampling volume and parameters tested affect comparisons. A missing denominator is shown as unavailable.

Monitoring history by year
YearResultsSamplesParametersListed exceedancesPer 1,000 results
20211,193756621.676
20221,4801016696.081
20231,6471056742.429
20241,700976610.588
20251,86210769136.982

Year-to-year detail

2025 compared with 2024

Changes describe dataset volumes only. The comparison uses the previous available year.

Results
20241,700
20251,862
+162
Listed exceedances
20241
202513
+12
Samples
202497
2025107
+10
Parameters
202466
202569
+3

Parameters with EPA-listed exceedances

Values and limits are reproduced as reported. Different unit/limit pairs are shown separately.

Aluminium

5 listed exceedance records / 107 tests4.67%

Descriptive frequency of records, not an official compliance measure.

Highest listed result
946 ug/l
Reported limit
200 ug/l
Records with this unit/limit pair
5
Latest exceedance
25 Jul 2025

pH

3 listed exceedance records / 107 tests2.80%

Descriptive frequency of records, not an official compliance measure.

Highest listed result
6.32 pH Units
Reported limit
9.5 pH Units
Records with this unit/limit pair
3
Latest exceedance
23 Jul 2025

Colony Count @ 22°C

2 listed exceedance records / 100 tests2.00%

Descriptive frequency of records, not an official compliance measure.

Highest listed result
163 1ml
Reported limit
100 1ml
Records with this unit/limit pair
2
Latest exceedance
06 Jan 2025

Coliform Bacteria

1 listed exceedance records / 107 tests0.93%

Descriptive frequency of records, not an official compliance measure.

Highest listed result
4 100ml
Reported limit
0 100ml
Records with this unit/limit pair
1
Latest exceedance
25 Jul 2025

Colour

1 listed exceedance records / 107 tests0.93%

Descriptive frequency of records, not an official compliance measure.

Highest listed result
31 Hazen
Reported limit
20 Hazen
Records with this unit/limit pair
1
Latest exceedance
07 Aug 2025

Iron

1 listed exceedance records / 107 tests0.93%

Descriptive frequency of records, not an official compliance measure.

Highest listed result
233 ug/l
Reported limit
200 ug/l
Records with this unit/limit pair
1
Latest exceedance
07 Aug 2025

Across the year

When were listed exceedances recorded?

Each point represents one listed exceedance record. Records on the same date remain separate.

Colour07 Aug 2025
31 HazenReported result
20 HazenReported limit
East Waterford Water Supply SchemeWater supply
JanFebMarAprMayJunJulAugSepOctNovDecAluminiumColiform BacteriaColony Count @ 22°CColourIronpH07 Aug 2025 — Colour: 31 Hazen; reported limit 20; East Waterford Water Supply Scheme; sample 4620/2508616/0107 Aug 2025 — Iron: 233 ug/l; reported limit 200; East Waterford Water Supply Scheme; sample 4620/2508616/0125 Jul 2025 — Aluminium: 226 ug/l; reported limit 200; East Waterford Water Supply Scheme; sample 4620/2507604/0225 Jul 2025 — Coliform Bacteria: 4 100ml; reported limit 0; East Waterford Water Supply Scheme; sample 4620/2507604/0123 Jul 2025 — Aluminium: 356 ug/l; reported limit 200; East Waterford Water Supply Scheme; sample 4620/2507601/0423 Jul 2025 — pH: 6.32 pH Units; reported limit 9.5; East Waterford Water Supply Scheme; sample 4620/2507601/0323 Jul 2025 — pH: 6.13 pH Units; reported limit 9.5; East Waterford Water Supply Scheme; sample 4620/2507601/0422 Jul 2025 — Aluminium: 946 ug/l; reported limit 200; East Waterford Water Supply Scheme; sample 4620/2507598/0122 Jul 2025 — Aluminium: 646 ug/l; reported limit 200; East Waterford Water Supply Scheme; sample 4620/2507598/0222 Jul 2025 — pH: 5.86 pH Units; reported limit 9.5; East Waterford Water Supply Scheme; sample 4620/2507598/0101 Apr 2025 — Aluminium: 257 ug/l; reported limit 200; East Waterford Water Supply Scheme; sample 4620/2504500/0106 Jan 2025 — Colony Count @ 22°C: 131 1ml; reported limit 100; East Waterford Water Supply Scheme; sample 4620/2501444/0106 Jan 2025 — Colony Count @ 22°C: 163 1ml; reported limit 100; East Waterford Water Supply Scheme; sample 4620/2501445/01

13 listed exceedance records across 6 parameters in 2025.

Your mapped supply

Water supply

Every Water Supply Zone used for this page's headline figures is included. Geographic overlaps are reported separately and are not added together or weighted by population.

East Waterford Water Supply Scheme

94.03% geographic overlap with the Tramore Built Up Area.

Technical mapping details
EDEN code
3800PUB1110
Local authority
Waterford
Page totals
Included
Spatial rank
1
Historical EPA scheme
Available
Latest monitoring year
2025

Detailed data

The complete parameter and listed exceedance tables for the reporting year.

69 parameter rows13 listed exceedance records107 samples
Show detailed data69 parameters · 13 exceedance records

Complete parameter index

All parameters in 2025

All parameters with test results or listed exceedance records in the latest reporting year
1,2-dichloroethane7002 Oct 20251
2,3,6-trichlorobenzoic acid7002 Oct 20251
2,4-D7002 Oct 20251
Acrylamide7002 Oct 20251
Aluminium107515 Dec 20251
Ammonium7002 Oct 20251
Antimony7002 Oct 20251
Arsenic7002 Oct 20251
Atrazine7002 Oct 20251
Bentazone7002 Oct 20251
Benzene7002 Oct 20251
Benzo(a)pyrene7002 Oct 20251
Bisphenol A7002 Oct 20251
Boron7002 Oct 20251
Bromate7002 Oct 20251
Cadmium7002 Oct 20251
Chlorfenvinphos7002 Oct 20251
Chloride7002 Oct 20251
Chromium7002 Oct 20251
Clopyralid7002 Oct 20251
Clostridium Perfringens7002 Oct 20251
Coliform Bacteria107115 Dec 20251
Colony Count @ 22°C100215 Dec 20251
Colour107115 Dec 20251
Conductivity107015 Dec 20251
Copper7002 Oct 20251
Cyanide7002 Oct 20251
Cypermethrin7002 Oct 20251
Dichlobenil7002 Oct 20251
Dichlorprop7002 Oct 20251
Diflufenican7002 Oct 20251
Diuron7002 Oct 20251
E. coli107015 Dec 20251
Enterococci107015 Dec 20251
Fluoride7002 Oct 20251
Free Chlorine107015 Dec 20251
Glyphosate7002 Oct 20251
Haloacetic acids (Sum of 5 HAAs)7002 Oct 20251
Iron107115 Dec 20251
Isoproturon7002 Oct 20251
Lead7002 Oct 20251
Linuron7002 Oct 20251
Manganese7002 Oct 20251
MCPA7002 Oct 20251
Mecoprop7002 Oct 20251
Mercury7002 Oct 20251
Metaldehyde7002 Oct 20251
Microcystin-LR7002 Oct 20251
Nickel7002 Oct 20251
Nitrate7002 Oct 20251
Nitrite (at tap)7002 Oct 20251
Odour100015 Dec 20251
PAH7002 Oct 20251
Pendimethalin7002 Oct 20251
Pesticides - Total7002 Oct 20251
pH107315 Dec 20251
Propyzamide7002 Oct 20251
Selenium7002 Oct 20251
Simazine7002 Oct 20251
Sodium7002 Oct 20251
Sulphate7002 Oct 20251
Sum of PFAS (sum of 20)7002 Oct 20251
Taste100015 Dec 20251
Tetrachloroethene & Trichloroethene7002 Oct 20251
Total Chlorine107015 Dec 20251
Total Organic Carbon7002 Oct 20251
Triclopyr7002 Oct 20251
Trihalomethanes(Total)7002 Oct 20251
Turbidity (at tap)107015 Dec 20251

Showing 69 of 69 parameters.

EPA exceedance dataset

Listed exceedances in 2025

Newest first. Sample IDs distinguish records that may otherwise look identical.

All listed exceedance records in the latest reporting year
DateParameterResultUnitReported limitWater supply / EDENSample ID
07 Aug 2025Colour31Hazen20East Waterford Water Supply Scheme
3800PUB1110
4620/2508616/01
07 Aug 2025Iron233ug/l200East Waterford Water Supply Scheme
3800PUB1110
4620/2508616/01
25 Jul 2025Aluminium226ug/l200East Waterford Water Supply Scheme
3800PUB1110
4620/2507604/02
25 Jul 2025Coliform Bacteria4100ml0East Waterford Water Supply Scheme
3800PUB1110
4620/2507604/01
23 Jul 2025Aluminium356ug/l200East Waterford Water Supply Scheme
3800PUB1110
4620/2507601/04
23 Jul 2025pH6.32pH Units9.5East Waterford Water Supply Scheme
3800PUB1110
4620/2507601/03
23 Jul 2025pH6.13pH Units9.5East Waterford Water Supply Scheme
3800PUB1110
4620/2507601/04
22 Jul 2025Aluminium946ug/l200East Waterford Water Supply Scheme
3800PUB1110
4620/2507598/01
22 Jul 2025Aluminium646ug/l200East Waterford Water Supply Scheme
3800PUB1110
4620/2507598/02
22 Jul 2025pH5.86pH Units9.5East Waterford Water Supply Scheme
3800PUB1110
4620/2507598/01
01 Apr 2025Aluminium257ug/l200East Waterford Water Supply Scheme
3800PUB1110
4620/2504500/01
06 Jan 2025Colony Count @ 22°C1311ml100East Waterford Water Supply Scheme
3800PUB1110
4620/2501444/01
06 Jan 2025Colony Count @ 22°C1631ml100East Waterford Water Supply Scheme
3800PUB1110
4620/2501445/01

Common questions

Frequently asked questions

Is Tramore tap water safe to drink?

WaterCheck Ireland does not issue a current safe or unsafe verdict. This page presents historical monitoring data. Check Uisce Éireann for any current Boil Water or Do Not Consume notices affecting your address.

Can you drink tap water in Tramore?

WaterCheck Ireland provides historical drinking-water monitoring data, not a current safe or unsafe verdict. For current Boil Water or Do Not Consume notices, check your Eircode with Uisce Éireann.

What is the tap water quality in Tramore?

In 2025, monitoring data for the Water Supply Zone mapped to Tramore included 1,862 results across 69 parameters. The separate EPA-listed exceedance dataset contains 13 records for those zones in 2025. These figures summarise historical records and are not a current safety verdict.

Who monitors drinking water quality in Tramore?

The historical monitoring figures shown here come from drinking-water datasets published by the Environmental Protection Agency (EPA), Ireland. Uisce Éireann operates public water supplies and publishes current supply notices.

What is a Water Supply Zone?

A Water Supply Zone is a defined area supplied by a public drinking-water system. Monitoring records apply to the zone as a whole, so sampling locations can be outside the Census Built Up Area.

What does a listed exceedance mean?

It is a record published in the separate EPA exceedance dataset. WaterCheck Ireland reproduces those records and does not infer additional exceedances or turn the record count into a safety assessment.

How can I check current water notices for my Eircode?

Use your Eircode on the Uisce Éireann website to check current Boil Water and Do Not Consume notices. This page is based on historical monitoring data and is not a live notice service.

Explore nearby reports

Water Quality Near Tramore

Nearest published Built Up Areas, ordered by straight-line distance between Census reference points.

Connected by mapped supply

Places sharing this Water Supply Zone

These published places share at least one Water Supply Zone used in this page's headline figures.

How this page is made

Sources and methodology

Settlement
Census 2022 Built Up Area: Tramore. Population refers to the whole Built Up Area.
Supply mapping
Uisce Éireann Water Supply Zone boundaries are matched geographically to the settlement.
Monitoring
EPA monitoring results and the separate listed exceedance dataset, 2021–2025.
Interpretation